Stainless Steel 5 values H Type

Stainless Steel 5 values H Type
Stainless Steel Straight Type | |||
NO | DESCRIPTION | QTY | MATERIAL |
1 | BODY | 1 | SS 316 |
2 | BONNET | 1 | SS 316 |
3 | STEM | 1 | SS 316 |
4 | BONNET PUSHER | 1 | SS316 |
5 | LOCK NUT | 1 | SS 316 |
6 | PACKING | 1 | TEFLON |
7 | WASHER | 1 | SS 316 |
8 | HANDLE | 1 | SS 304 |
9 | GRUB SCREW | 1 | SS |
10 | DUST CAP | 1 | PLASTIC |
11 | LOCKING PIN | 1 | SS 304 |
12 | BONNET SEAL | 1 | TEFLON |
FEATURES :
5 VALVE MANIFOLDS (STRAIGHT TYPE)
- 5 valve manifolds are designed for remote or separate mounting.Connecting from process side 1/2″ NPT(F) and Instrument side 1/2″ NPT(F) Connecting system impulse lines and transmitters, having simple three valves configuration which allows for easy two block or Isolate, one Equaliser valve calibration of a static pressure transmitter or gauge.
- Bleed/vent connection with s.s. plug will be provided on request.
- Approximate weight : 0.95 Kg (2.1 Lbs.).
- Heat code traceability
BONNET ASSEMBLY
- Screwed bonnet design.
- Bonnet-back seated blow out proof.
- Spindle-Ground and thread rolled.
- Spindle tip-Non rotating tip shut off type – stellited, Regulating-stellited and soft seated.
- Bonnet pusher – silver plated for anti galling freezing for increased stem cycle life.
- Dust cap protects stem threads from externals contamination.
- Leak tight seal with low operating torque.
Size : | 1/4″, 1/2″ |
End connection : | NPT,BSPT,Socket weld. |
Working Pressure : | 6000 Psi (413 Bar) |
Temperature Rating : | PTFE 450 Deg. F (232 Deg.C) Grafoil 700 Deg. F(371 Deg. C) |
Material of construction : | SS 316, SS 304, Monel,C.S. |
Optional Sour Gas service valves are available confirming to NACE Std. MR – Jan-75 | |
Stem packing : | PTFE, Grafoil. |
Orifice : | Dia. 4.0 |
All valves are 100% Factory tested prior to shipment. |
APPLICATIONS
Refineries,liquid patroleum gas processing plant,petro-chemical plants, systems difficult to shur off due to solid contents dust, rust, dirt etc.
MANIFOLDS SELECTION INFORMATION DATA
Pressure &2500
TESTING
Pneumatic Seat test is performed at 1/4 of working pressure.
Hydrostatic shell test is performed at 1.5 times the working pressure.
Optional test are available upon request.
LUBRICATIONS
Dye Molly Sulphide.